Welcome to the official website of Shenzhen Yukun Technology Co., Ltd!

Consulting phone:

135-3037-2041

(Mr.Wang)

Capacitor Module
Your current location : Home >> Products >> Super capacitor

Contact UsContact Us

Shenzhen Yukun Technology Co., Ltd

Contact: Mr. Wang

Wob: 13530372041

Tel: 0755-26607151

Email: Jim@sznovelty.cn

Web: en.szsyky.cn

Add: Fudali 302, No. 8, Shuitian Hongxing Road, Bao'an District, Shenzhen

Gold capacitor

Gold capacitor

  • Cname:Super capacitor
  • Views:Times
  • Release date:2023-02-17 16:05:01
  • Content
  • Features
  • Parameter

Product introduction:

       Gold capacitance generally refers to farad capacitance. Farad capacitor, also known as double-layer capacitor, gold capacitor and supercapacitor, is a chemical element developed from the 1970s and 1980s. Supercapacitors store energy through polarized electrolytes without chemical reaction, and the process of energy storage is reversible, which is precisely because this supercapacitor can repeatedly charge and discharge hundreds of thousands of times.

Product specification:

projectcharacteristic
Rated voltage 2.7V
Capacity 2F
Working temperature - 40 ℃ - 65 ℃
Tolerance 0+30%
Temperature characteristics 

from - 40 ℃ to 65 ℃ Capacity change: △ c ∠ 30% of initial measured value @ 25 ℃ Internal resistance change: △ ESR ∠ 100% of nominal value

Under high temperature load life of 25 ℃ and rated voltage, load 1000h capacity change: △ c ∠ 30% of initial measured value @ 25 ℃ internal resistance change: △ ESR ∠ 200% of nominal value
Under normal temperature load life of 25 ℃ and rated voltage, load capacity change in 10 years: △ c ∠ 30% of initial measured value @ 25 ℃ internal resistance change: △ ESR ∠ 200% of nominal value
Under normal temperature cycle life of 25 ℃, after 500000 charge-discharge cycles (from rated voltage to 1/2 rated voltage), capacity change: △ c ∠ 30% of initial measured value @ 25 ℃ internal resistance change: △ ESR ∠ 200% of nominal value

Product performance table:

Model voltage Vcapacity FAC internal resistance m Ω 1KHz24h leakage current uA

Product size mm

Diameter D length H foot distance P
YKY08122R7E105RPJ2.71300108123.5
YKY08122R7E205RPJ2.72200208123.5
YKY08162R7E205RPJ2.72130208163.5
YKY08202R7E335RPJ2.73.3120338203.5
YKY10202R7E505RPJ2.75705010205
YKY10202R7E705RPJ2.77807010205
YKY10252R7E106RPJ2.7105010010255
YKY13202R7E106RPJ2.7105010013205
YKY13252R7E186RPJ2.71860
18013255


Dimensions (unit: mm)

尺寸-1.jpg


Product display:

Gold capacitor

未标题-1副本.jpg


Product packaging:

2.7-3.0-1.jpg


Product advantages:

Application areas:

[~]P`CO9T}7YQI[(0(}~%%E.png

testing method:

   1. Electrostatic capacity test method:

(1) Test principle

    The test of the electrostatic capacity of the supercapacitor is to use the method of constant current discharge of the capacitor, and calculate it according to the formula.

   C=It(U1-U2)

In the formula: C - electrostatic capacity, F;

       I-constant discharge current, A;

      U1, U2 - use voltage, V;

      t-Discharge time required for U1 to U2, S

(2), test procedure

   Charge the capacitor with a current of 100A, charge the capacitor to the working voltage and keep the voltage constant for 10 seconds, then discharge the capacitor with a current of 100A, take U1 as 1.2V and U2 as 1.0V, record the discharge time within this voltage range, and the total cycle Capacitance, take the average value.

2. Stored energy test

  (1) Test principle:

      The test of supercapacitor energy is carried out by the method of discharging the capacitor with constant power to 1/2 of the working voltage with a given voltage range of the capacitor. The output energy W of the capacitor is obtained from the relationship between the constant discharge power P and the discharge time T, namely:

          W=PT

  (2) Test procedure

     Charge the capacitor to the working voltage with a constant current of 100A, and then keep it constant until the charging current drops to the specified current (10A for traction type, 1A for start-up type), after 5 seconds of rest, discharge the capacitor with constant power to 1/2 of the working voltage, record Discharge time and calculate magnitude. Repeat the measurement 3 times and take the average value.

3. Equivalent series resistance test (DC)

  (1) Test principle

    The internal resistance of the capacitor is measured according to the sudden change of the voltage within 10 milliseconds of the capacitor disconnecting the constant current charging circuit. That is: in the formula:

     R - the internal resistance of the capacitor;

     U0 - capacitor cut off the voltage before charging;

     Ui - cut off the voltage within 10ms after charging;

     I - cut off the current before charging.

 (2) Measurement process

    Charge the capacitor with a constant current of 100A, disconnect the charging circuit when the charging working voltage is 80%, use a sampling machine to record the voltage change value within 10 milliseconds after the capacitor is powered off, and calculate the internal resistance, repeat 3 times, and take the average value.

4. Leakage current test

   After charging the capacitor to the rated voltage with a constant current of 100A, charge the capacitor with a constant voltage for 30min at this voltage value, and then leave it open for 72h. During the first three hours, the voltage value was recorded every minute, and during the remaining time, the voltage value was recorded every ten minutes.

  Calculate the self-discharge energy loss, SDLF=1-(V/VW)2, and the calculation time points are: 0.5, 1, 8, 24, 36, 72h.

   Note: The voltage tester must have high input impedance to minimize the impact of discharge.



Next:Farad ion capacitance2023-02-17

Recently Viewed: