Product introduction:
Hybrid capacitor monomer generally refers to double-layer capacitor, which is a kind of supercapacitor and a new type of energy storage device. The double-layer capacitance is between the battery and the capacitance, and its huge capacity can be used as a battery completely. Compared with the battery based on electrochemical principle, the charge and discharge process of the double-layer capacitor does not involve the change of material at all, so it has the characteristics of short charging time, long service life, good temperature characteristics, energy saving and green environmental protection. The distance between the two electric layers of the double-layer capacitor is very small, which makes the withstand voltage very weak, generally not more than 20V, so it is usually used as the energy storage element in low voltage DC or low frequency situations.
Series Specification Sheet:
series name | series | |||||||
type name | YKY-2R7 | |||||||
Rated voltage VR | 2.7V | |||||||
surge voltage | 2.85V | |||||||
Capacity range | 120F-3000F | |||||||
Operating temperature range | -40℃~+85℃ | |||||||
Product life | Normal temperature cycle life: 25°C, 500,000 cycles between VR and 1/2VR , capacity decay ≤30%, internal resistance change ≤4 times | |||||||
High temperature endurance life: 85℃, keep VR , 1000 hours, capacity decay ≤30%, internal resistance change ≤4 times |
Product performance table:
model | Voltage V | Capacity F | AC internal resistance mΩ1KHz | 24h leakage current uA | Product size mm | ||
Diameter D | length H | Pitch P | |||||
YKY-2R7-J127VYJ28 | 2.7 | 120 | 15 | 1200 | 22 | 46 | 10 |
YKY-2R7-J157VYJ29 | 2.7 | 150 | 15 | 1500 | 25.4 | 40 | 10 |
YKY-2R7-J207VYJ33 | 2.7 | 200 | 10 | 2000 | 35 | 61 | 10 |
YKY-2R7-J207VYJ31 | 2.7 | 200 | 10 | 2000 | 35 | 61 | 10 |
YKY-2R7-J207VYJ30 | 2.7 | 200 | 10 | 2000 | 25.4 | 54 | 10 |
YKY-2R7-J227VYJ31 | 2.7 | 220 | 10 | 2200 | 30 | 50 | 10 |
YKY-2R7-J227VYJ33 | 2.7 | 220 | 10 | 2200 | 35 | 61 | 10 |
YKY-2R7-J307VYJ32 | 2.7 | 300 | 10 | 3000 | 35 | 54 | 10 |
YKY-2R7-J307VYJ31 | 2.7 | 300 | 10 | 3000 | 30 | 50 | 10 |
YKY-2R7-J407VYJ33 | 2.7 | 400 | 10 | 4000 | 35 | 61 | 10 |
YKY-2R7-J477UNJ34 | 2.7 | 470 | 5 | 4700 | 35 | 96 | 10 |
YKY-2R7-J707UNJ34 | 2.7 | 700 | 5 | 6500 | 35 | 96 | 12.7 |
YKY-2R7-J108UNJ71 | 2.7 | 1000 | 5 | 10000 | 51 | 71 | 21.8 |
YKY-2R7-J128UNJ49 | 2.7 | 1200 | 3 | 12000 | 51 | 108 | 21.8 |
YKY-2R7-J158UNJ49 | 2.7 | 1500 | 3 | 15000 | 51 | 108 | 21.8 |
YKY-2R7-J208UNJ50 | 2.7 | 2000 | 2 | 20000 | 51 | 133 | 21.8 |
YKY-2R7-J308UNJ52 | 2.7 | 3000 | 2 | 30000 | 64 | 133 | 28.2 |
Product Size:
product application:
1) Portable equipment: notebook computer, video camera, PDA, digital camera, portable DVD, etc
2) Household appliances: two-way radios, walkie talkies, electric toys, electric bicycles, emergency lighting
3) Military equipment
4) Medical treatment
5) Electric tools
testing method:
capacity
1 Constant current discharge method
(1) Measurement circuit
Figure 1 - Constant Current Discharge Method Circuit
2 Measurement method
◎ The DC voltage of the constant current/constant voltage source is set to the rated voltage (UR ) .
◎ Set the constant current value of the constant current charging and discharging device specified in Table 1.
◎ Switch the switch S to the DC power supply, and charge it with constant voltage for 30 minutes after the constant current/constant voltage source reaches the rated voltage.
◎ After charging, switch the switch S to a constant current discharge device to discharge with a constant current.
◎ Measure the time t1 and t2 of the voltage across the capacitor from U1 to U2, as shown in Figure 2, and calculate the capacitance value according to the following equation :
Figure 2 Terminal voltage characteristics of capacitors
in
C capacity (F);
I discharge current (A);
U1 measures the initial voltage (V) ;
U 2 measures the termination voltage (V);
t 1 Time (s) for the discharge voltage to reach U1;
t 2 Time (s) for the discharge voltage to reach U2.
See Table 1 for the discharge current I and the voltages U1 and U2 at which the discharge voltage drops .
3 Equipment: A, ARBIN supercapacitor test system B, linear DC stabilized power supply C, constant current discharge device D, voltage recorder
Internal resistance
Test method: AC impedance method
Measurement circuit
The measurement circuit shown is tested.
Figure 3 - AC Impedance Method Circuit
Measurement methods
The internal resistance Ra of the capacitor should be calculated by the following formula:
in
Ra AC internal resistance (Ω);
U RMS value of AC voltage (V rms);
I AC current rms value (V rms).
The frequency at which the voltage is measured, should be 1kHz.
The AC current should be 1mA to 10mA.